HVLS Ceiling Ventilation Cooling Fan

HVLS Ceiling Ventilation Cooling Fan is energy saving based on PMSM (permanent magnet synchronous motor). with 260N.m torque, the driving force is more stronger and the torque is more stable. Save 30% energy, IE4 high efficiency, the fan diameter from 2.5M to 7.3M, 14850m³ min air volume, free maintenance for life, no need to change oil and seal. 20-years reliable life, better preformance lower energy consumption and longer life.

Model W26 W24 W22 W20 W18 W16 W14 W12 W10
Specifications/diameter(m) 8 7.3 6.7 6.1 5.5 4.9 4.2 3.6 3.1
Speed range(rpm) 10-45 10-55 10-60 10-60 10-70 10-75 10-80 10-85 10-90
Full load air volume(m³/min) 16870 16130 14800 14200 12800 11800 10800 8900 7800
Rated Power(kw) 1.5-1.1 0.75 0.4
Average energy consumption(kW·h) ≤1.2 ≤1.0 ≤0.7 ≤0.4
Motor noise(dB) 39
Power parameters(V) 380V/220S
Full load current(A) 2.8(380V)/4.6(220V) 2.6(380V)/3.0(220V) 2.5 2.0
Machine weight(kg) 108 92 90 73 63 60 47 42 39
Blade length(mm) 3650 3297 3070 2770 2470 2162 1826 1522 1280
Measured
diameter(mm)
7952 7209 6747 6075 5514 4861 4175 3539 3057

Motor system:PMS motor

1.More stronger:260N.m torque,more stronger,more stabler torque,air volume increases 30%.
2.More efficient:Unique outer rotor high torque design,higher accuracy.
3.More energy saving:30% energy saving,up to IE4 high-efficiency energy-saving standards,GB30253-2013 national energy efficiency new standard.
4.Free maintenance for life :Totally sealed,no need to replace lubricating oil,seals and other accessories,more cost-effective.
5.Lower noise:38db lower noise,more comfortable.
6.Lower temperature:Motor raised temperature lower than 35℃,longer life.

Vfd:Vector converter

1.More steady:New generation of high-reliability IGBT modules,Motor vector algorithm and current suppression let the start more steady.
2.More quiet:Up to 16KHZ,no noise during the speed up, slow down and running.
3.More reliable:PCBA three-proof paint treatment,durable and long life.
4.Restart: It can smooth restart when the blades not completely stopped.
5.Failure protection:More than 25 fail-safe protections (over current and voltage,under voltage,phase loss,overload,etc.)

Blades- Airflow components

1.Blade design-Streamline variable cross-section
Conform to aerodynamic equal chord length theory,combined with the relative linear velocity principle,the blade narrows(304-186mm) and thins(43mm-21mm) from root to tip till tail then widen,the air is more even and uniform.
2. Blade material-Aviation aluminum alloy
1. 5mm thickness No.5052H32 aviation aluminum alloy original plate,precision CNC molding,high strength and flexibility ensure the blade not to be broken.
3. Blade weight-More lighter and safer
6. 7kg per blade(24ft),less blades,lighter weight,it can reduces the motor load,prolong the life,more safe and cost-efficient.

Connection:Safety Anti-fall Structure

  1. Blade and petiole
    Mortise and tenon connection:
    The convex petiole with concave buffer device form the Joint engaged,eliminate the centrifugal force from the blades when the fan is running and the shear force when the fan starts and stops.
    The transverse screw is the same direction with fan running track to avoiding the shear in order to ensure the blade will not broken,eliminate the possible Safety hazards radically.
  2. Petiole and wheel hub
    The petiole and hub/motor are integrated by the stepped concave-convex sections to engage each other.The overall structure is used to withstand the centrifugal force during running,and all fasteners are not stressed.
  3. Motor and flange roulette
    Safety ring:Connect the 5 petioles and motor upper cover form the whole,adopt the occlusion structural to even the force of the whole fan.
    Anti-falling roulette:The concave flange roulette engaged with the convex anti-falling ring each other under the gravity to ensure the reliable connection between the flange roulette and motor.

For Horse Stable